XPS Extruded Polystyrene

Insu Foam

Insutech InsuFoam is a rigid, blue Extruded Polystyrene Foam (XPS) board manufactured at a density of 36–40 kg/m³ through a continuous extrusion process.

Density36–40 kg/m³
λ Value0.033 W/mK
Thickness20 – 100 mm
Insu Foam
Product Overview

Engineered for the job it protects.

Insutech InsuFoam is a rigid, blue Extruded Polystyrene Foam (XPS) board manufactured at a density of 36–40 kg/m³ through a continuous extrusion process. Cut to precise dimensions and available in lapped or straight edge profiles, InsuFoam delivers consistent quality, reliable fitment, and outstanding mechanical strength across the full range of industrial and commercial insulation assemblies.

With a thermal conductivity of 0.033 W/mK and compressive strength of 300 kPa, Insutech InsuFoam effectively reduces heat transfer through building envelopes and withstands the highest structural loads in the XPS range — minimising reliance on mechanical cooling and heating systems, cutting electricity consumption, and lowering CO₂ emissions over the building’s full service life.

Key Features
  • Highest compressive strength in the XPS range: 300 kPa @ 10% deformation
  • Superior thermal insulation with 0.033 W/mK thermal conductivity
  • Significantly reduces electricity consumption and energy operating costs
  • Reduces CO₂ emissions through superior insulating performance
  • Excellent water resistance: water absorption ≤0.7% by volume
  • Prevents moisture infiltration in walls, floors, and roof assemblies
  • Lightweight and easy to handle, bond, and install on site
Available Options

Thicknesses

20 – 100 mmCustomized

Edge Profiles

Straight EdgeLapped Edge
Technical Data

Insufoam Specs

PropertyCodeTest MethodUnitResult
Densitykg/m336–40 ± 5%
Thermal ConductivityλDEN 12667:2004W/mK0.033 W/mK
Thermal Resistance (20 mm)RDEN 12667:2004(m²K)/W0.6
Thermal Resistance (30 mm)RDEN 12667:2004(m²K)/W0.9
Thermal Resistance (40 mm)RDEN 12667:2004(m²K)/W1.2
Thermal Resistance (50 mm)RDEN 12667:2004(m²K)/W1.5
Thermal Resistance (60 mm)RDEN 12667:2004(m²K)/W1.8
Compressive Strength (@10% deformation)CS(10/Y)EN 826:2013kPa≥ 300 kPa
Dimensional StabilityDS(TH)EN 1604%<5
Fire RatingEuro ClassEN 13501-1EuroclassE
Specific HeatEN 12524J/(kgK)1200
Water Diffusion ResistanceMUEN 12086:2013μ≥200
Water Absorption by ImmersionWL(T)EN 12087% vol≤0.7
Tensile Strength Perp. to Faces (30 mm)EN 1607:2013kPa0.9
Tensile Strength Perp. to Faces (50 mm)EN 1607:2013kPa1.5
Temperature Limit°C70

*Insutech reserves the right to modify product specifications, descriptions, and technical information at any time without prior notice.

Installation

Application, Step by Step.

01 / 06
01Prepare the substrate

Remove dust, grease and loose particles from the substrate so the insulation boards can sit completely flush against the prepared surface.

02Measure and cut

Measure carefully and cut the boards to size with a sharp blade or hot wire, keeping the edges square for tight and accurate joints.

03Apply adhesive or fasteners

Apply a compatible adhesive or fix mechanical fasteners appropriate to the substrate, following the specified coverage and spacing.

04Position and secure

Position each board and press it firmly into place, butting boards tightly together and staggering the joints between rows for stability.

05Seal joints and gaps

Close all joints and gaps with compatible tape or filler so the insulation layer forms one continuous, unbroken thermal envelope.

06Install the finishing layer

Apply the specified screed, render or cladding over the boards to protect the insulation and complete the build-up as designed.

Application Tutorial

Storage

Check Insutech's Storage Guide for full guidance on storing this product.

Storage Guide

Let's Talk BusinessReady for Pricing or Export Support?