EPS Expanded Polystyrene

EPS 17kg/

Insutech EPS 17 is a white expanded polystyrene foam sheet at a nominal density of 17 kg/m³, delivering improved mechanical strength and thermal performance over the entry-level Insutech EPS 14 grade.

Density17 kg/m³
λ Value≤ 0.036 W/mK
ThicknessCustomized
EPS 17kg/m³
Product Overview

Engineered for the job it protects.

Insutech EPS 17 is a white expanded polystyrene foam sheet at a nominal density of 17 kg/m³, delivering improved mechanical strength and thermal performance over the entry-level Insutech EPS 14 grade. Precision-cut from injection-moulded polystyrene blocks, it offers excellent dimensional consistency and integrates seamlessly into both new construction and retrofit insulation assemblies.

Insutech EPS 17 provides enhanced compressive resistance alongside a thermal conductivity of ≤ 0.036 W/mK, making it effective at reducing heat flow through building envelopes. By limiting thermal bridging and minimising energy losses, it contributes to measurable reductions in electricity bills and supports the delivery of energy-efficient, sustainable buildings.

Board thickness: Available in 20 mm – 100 mm and can also be customized.

Key Features
  • Enhanced thermal insulation with ≤ 0.036 W/mK thermal conductivity
  • Improved compressive strength over EPS 14 grade
  • Reduces electricity consumption and operating energy costs
  • Reduces CO₂ emissions through superior insulating performance
  • Lightweight and easy to handle and install
  • Prevents moisture infiltration in walls and ceilings
  • Resistant to moisture and chemical attack
Available Options

Thicknesses

Customized

Shapes

Customizable
Technical Data

Technical Data

PropertyCodeTest MethodUnitResult
Densitykg/m317 ± 5%
Thermal ConductivityλDEN 12667W/mK0.036 W/mK
Thermal Resistance (30 mm)RDEN 12667(m²K)/W0.84
Thermal Resistance (40 mm)RDEN 12667(m²K)/W1.12
Thermal Resistance (50 mm)RDEN 12667(m²K)/W1.41
Thermal Resistance (60 mm)RDEN 12667(m²K)/W1.69
Compressive StressCS(10/Y)EN 826kPa≥ 80 kPa
Tensile StrengthTREN 1607kPa≥ 80 kPa
Bending StrengthBSEN 12089kPa≥ 130 kPa
Dimensional StabilityDS(70)3EN 1604%≤ 3
Specific HeatEN 12524J/(kgK)1450
Water Vapour DiffusionMUEN 12086μ20–40
Water Absorption (Immersion)WL(T)EN 12087% vol≤ 3
Water Absorption (Diffusion)WD(V)EN 12088% vol≤ 3
Max. Service Temperature°C75
Fire RatingEN 13501-1EuroclassE

*Insutech reserves the right to modify product specifications, descriptions, and technical information at any time without prior notice.

Installation

Application, Step by Step.

01 / 06
01Prepare the substrate

Remove dust, grease and loose particles from the substrate so the insulation boards can sit completely flush against the prepared surface.

02Measure and cut

Measure carefully and cut the boards to size with a sharp blade or hot wire, keeping the edges square for tight and accurate joints.

03Apply adhesive or fasteners

Apply a compatible adhesive or fix mechanical fasteners appropriate to the substrate, following the specified coverage and spacing.

04Position and secure

Position each board and press it firmly into place, butting boards tightly together and staggering the joints between rows for stability.

05Seal joints and gaps

Close all joints and gaps with compatible tape or filler so the insulation layer forms one continuous, unbroken thermal envelope.

06Install the finishing layer

Apply the specified screed, render or cladding over the boards to protect the insulation and complete the build-up as designed.

Storage

Check Insutech's Storage Guide for full guidance on storing this product.

Storage Guide

Let's Talk BusinessReady for Pricing or Export Support?